Low volt. cables_basket

HOME > Prysmian Kable > Product > Low volt. cables_basket
  • SPREADERFLEX 3GSLTOE 0.6/1kV
  • Spreader cable for basket operation

주요특징
Model SPREADERFLEX 3GSLTOE 0.6/1kV
Application Feeder cable for load-lifting equipment, e.g. spreader with high mechanical stress in gravity-fed collector basket operation, with voltage rate up to 0,6/1 kV. Suitable for operation in cold environment.
Global data [Brand] : SPREADERFLEX
[Type designation] : 3GSLTOE-J/-O
[Standard] : based on DIN VDE 0250
[Certifications / Approvals] : GOST-R
Design features [Conductor] :
Bare Electrolytic copper, extremely fine stranded, class FS
[Insulation] :
Special EPR compound based on type 3GI3 acc. DIN VDE 0207; for application in ambient
temperatures down to -40°C
[Core identification] :
Optimal identification as a result of light colored insulation with numbers printed in black;
protective earth conductor green/yellow
[Individual screen] :
Braid screen made of tinned copper wires. Transfer impedance optimized at 30 MHz.
Surface covered: at least 60% for shielded cores; at least 80% for twisted pairs
[Core arrangement] :
Core assembly: cores laid-up into bundles;
Bundle assembly: bundles laid-up around the central support element.
[Support element] :
Aramide threads woven round lead ball cords, arranged centrally. The breaking load is rated to
provide a safety factor of 5 when the cable is suspended vertically for 50 m. In case of bigger
cross-section and higher number of cores, the support element is a round rubber filler with Aramid
threads.
[Outer sheath] :
Special PUR compound;
Colour: black
[Marking] :
SPREADERFLEX 3GSLTOE-J (number of cores) x (cross-section)
Electrical parameters [Rated voltage] : 0.6/1 kV (600/1000V)
[Max. permissible operating voltage AC] : 0.7/1.2 kV
[Max. permissible operating voltage DC] : 0.9/1.8 kV
[AC Test Voltage] : 3.5 kV (5 Min.)
[Data transmission] : With special bus elements: ASI-Bus, Profibus or use of fibre optics elements for trouble-free data transmission.
[Current Carrying Capacity description] : According to DIN VDE 0298, Part 4