Low volt. reeling cables_E-RTGs

HOME > Prysmian Kable > Product > Low volt. reeling cables_E-RTGs
  • CORDAFLEX(SMK) (N)SHTOEU
  • Low voltage reeling cable for E-RTG‘s

주요특징
Model CORDAFLEX(SMK) (N)SHTOEU
Application Flexible low voltage reeling cable for power supply (also with integrated fiber optics), suitable for application under high and very high mechanical stresses. The main application is reeling operation on ERTG's (Electrified Rubber Tyred Gantry cranes).
Global data [Brand] : CORDAFLEX(SMK)
[Type designation] : (N)SHTOEU-J/-O
[Standard] : Based on DIN VDE 0250-814
[Certifications / Approvals] : VDE Reg. Nr. 7519; GOST-R
Design features [Conductor] :
Electrolytic copper tinned, very finely stranded class FS
[Insulation] :
PROTOLON MS
Special compound based on high-quality EPR (min. 3GI3); improved mechanical and electrical characteristics.
[Core identification] :
Best identification as a result of light colored insulation with numbers printed in black for power and control cables, earth conductor green-yellow colored.
[Optical Fiber] :
Fibre core diameter: 62.5, 50 or 9μm; diameter across the cladding: 125μm; diameter over the coating: 250μm.
Design available with 6,12, 18 or 24 fibres.
More details on the Catalog.
[Fiber coding] :
Specially developed color code for identification of the individual fibres
[Fiber covering] :
Hollow core with filling compound, Basic material: ETFE, Compound: 7YI 1, Natural color
[Core arrangement] :
Laid-up in a maximum of 3 layers
[Sheath system] :
- PROTOFIRM Special - Inner sheath:
High grade special compound based on PCP, color: yellow;
- Anti-torsion braid:
Reinforced braid made of polyester threads, in a vulcanized bond between the sheaths, resulting in a high strength of the sheath system;
- PROTOFIRM Special - Outer sheath:
A sheath system with a unique combination of flexibility and robustness has been achieved through the use of this structure. Abrasion and tear resistant special rubber compound based on PCP, color: yellow.
[Marking] :
CORDAFLEX (SMK) (N)SHTOEU -J/-O (number of cores) x (cross section)+VDE Reg.-Nr.
Electrical parameters [Rated voltage] : 0.6/1 kV (600/1000V)
[Max. permissible operating voltage AC] : 0.7/1.2 kV
[Max. permissible operating voltage DC] : 0.9/1.8 kV
[AC Test Voltage] : 3.5 kV (5 Min.)
[Data transmission] : Special design with fibre-optics for trouble free data transmission at high data rates.
[Current Carrying Capacity description] : Acc. to DIN VDE 0298-4